Insulation Resistance
|
Test Voltage
|
250V/500V/1000V
|
Measuring Ranges
(Mid-scale Value)
|
20MΩ/200MΩ/2000MΩ
|
Output Voltage
on open circuit
|
Rated test voltage+20%, -0%
|
Nominal Current
|
1mA DC min.
|
Output Short
Circuit Current
|
1.5 mA DC approx.
|
Accuracy
|
|±1.5%rdg±5dgt (20MΩ/200MΩ)
|±10%rdg±3dgt (2000MΩ)
|
Continuity Test
|
Measuring Ranges
(Mid-scale Value)
|
20Ω/200Ω/2000Ω
|
Output Voltage
on open circuit
|
7~12V DC
|
Measuring Current
|
200mA DC min.
|
Accuracy
|
|±1.5%rdg±5dgt (20Ω)
|±1.5%rdg±3dgt (200Ω/2000Ω)
|
AC Voltage
|
AC Voltage range
|
0-600V AC
|
Accuracy
|
|±5%rdg±3dgt
|
General
|
Safety Standard
|
IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
|
IP Rating
|
IEC 60529-IP54
|
EMC Standard
|
IEC 61326-1
|
Withstand Voltage
|
3700V AC for 1 minute
|
Power Source
|
R6P (AA) (1.5V) × 8
|
Dimensions
|
185(L) × 167(W) × 89(D)mm
|
Weight
|
970g approx
|
Accessories
|
7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6P (AA) × 8, Shoulder Strap
Instruction Manual
|