DC V
|
340mV/3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
|
AC V
|
3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50~400Hz]
|
DC A
|
100A ±2%rdg±5dgt
|
AC A
|
100A ±2%rdg±5dgt (50/60Hz)
|
Ω
|
340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt (0~340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
|
Continuity buzzer
|
Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
|
Frequency
|
(AC A) 3.4/10kHz ±0.1%rdg±1dgt
(AC V) 3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 25A, Voltage: more than 30V)
|
Conductor size
|
φ10mm max.
|
Withstand Voltage
|
3700V AC for 1 minute
|
Applicable standards
|
IEC 61010-1 CAT.III 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
|
Power Source
|
R03 (DC 1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
|
Dimensions
|
128(L) × 91(W) × 27(D)mm
|
Weight
|
220g approx.
|
Accessories
|
R03 (DC 1.5V) × 2, Instruction Manual
|
Optional
|
9107 (Carrying case [Soft])
|